Dianbida Power Equipment (Jiangsu) Co., Ltd.
+86 18112146366
Contact Us

    Address: No. 23, Nanhuan Road, Jiangdu District, Yangzhou City, Jiangsu Province

    Phone: +86 18112146366

    Fax : +8618112146366

    Email:dianbidapower@gmail.com

 

Industrial Diesel Generator Set for Heavy-Duty Industrial Power Supply

 

Industrial diesel generator sets are designed for continuous and high-load power supply in factories, construction sites, mining operations, data centers, and large infrastructure projects.

 

 
 
 
Features
 
01/

Stable Load Output
Equipped with an AVR (±1–1.5%) and brushless alternator for stable voltage and frequency under 50–100% continuous load.

02/

High Motor Starting Capacity
Supports 1.5–2× surge power, suitable for pumps, compressors, crushers, and motor-driven equipment.

03/

Harsh Environment Design
Optional IP23–IP54 enclosure with anti-corrosion frame, suitable for dust, heat, rain, and outdoor industrial sites.

04/

Continuous Operation Cooling System
Industrial radiator and forced air cooling system support stable operation in ambient temperatures up to 40–50°C.

 

Power Range Classification

 

50–200KW – LIGHT INDUSTRIAL USE

 

Suitable for small factories and auxiliary systems.
Small production lines
Workshop equipment
Lighting systems
Backup for small commercial facilities

200–800KW – MEDIUM INDUSTRIAL USE

 

Most commonly used range for industrial operations.
Manufacturing plants
Construction machinery support
Medium-scale factories
Commercial building backup power

800–3000KW+ – HEAVY INDUSTRIAL USE

 

Designed for large-scale continuous operation.
Mining operations
Large manufacturing plants
Data centers
Infrastructure and energy projects

 

Customization Options

 

Item

Customizable Options

Power Output

50–200kW / 200–800kW / 800–3000kW+

Engine Type

Inline 4-cylinder / 6-cylinder / V-type diesel engine

Starting System

Electric start / ATS automatic transfer system

Alternator Type

Brushless alternator (industrial grade)

Enclosure Type

Open type / Silent canopy (IP23–IP54)

Protection Level

IP23 / IP44 / IP54

Control System

Standard control panel / PLC intelligent control system

Operation Mode

Standby / Prime power / Continuous duty

Cooling System

Standard radiator / Heavy-duty cooling system (40–50°C)

Voltage Output

400V / 380V / 11kV

System Integration

Standalone / ATS system / Parallel operation system

Fuel Tank

Base tank / Extended runtime fuel tank

 

Technical Parameters

 

Item

Specification

Power Range

10kW – 2000kW

Voltage

220V – 690V

Frequency

50Hz / 60Hz

Phase

Single / Three Phase

Power Factor

0.8

Cooling System

Water-cooled

Starting Method

Electric start

Control System

Digital controller

Operation Mode

Prime Power

 

 

Installation Requirements

• A stable, level foundation with vibration isolation and service clearances.

• Proper ventilation and exhaust routing to prevent overheating and fume recirculation.

• Correct fuel system design (tank, piping, filtration, safety containment).

• Safe electrical integration (ATS, protection devices, grounding/bonding).

• Commissioning tests including ATS function and load steps with documented results.

Marine Diesel Generator Set

 

Packaging & Shipping

 

Lead Time

15–25 working days

Packaging

Generators are packed with shockproof, plywood, and waterproof materials to prevent damage during transportation

Payment Method

T/T, Trade Assurance, Paypal, Western Union, Credit Card, L/C etc.

Shipping

Sea freight, air freight, and express delivery options are available

productcate-1-1

 

Our Certificates

 

 

productcate-1-1

 

FAQ

 

Q: How do I determine the correct generator size for my project?

A: You need to calculate the total running load and starting load of all connected equipment. In industrial applications, it is generally recommended to select a generator with a 1.2–1.5× safety margin above the total calculated load to avoid overload during peak operation or motor startup conditions.

Q: Can the generator be used as a primary power source or only for backup?

A: It can be configured for both applications. As a standby power system, it operates during grid failure. As a prime power unit, it can run continuously in off-grid or unstable grid environments. The engine rating, cooling system, and duty cycle are selected based on the required operation mode.

Q: How does the generator handle sudden high starting loads from industrial equipment?

A: Industrial diesel generators are designed for motor starting conditions. With 1.5–2× surge power capacity, they can support high inrush current from equipment such as compressors, pumps, crushers, and heavy machinery without causing voltage collapse.

Q: Can the generator operate in outdoor or remote environments?

A: Yes. Industrial units are designed for harsh working conditions. Depending on configuration, they can be equipped with IP23 to IP54 protection enclosures, reinforced steel frames, and anti-corrosion treatment, making them suitable for construction sites, mining areas, and remote installations.

Q: How is the generator integrated into a building or industrial power system?

A: Integration is typically achieved through an ATS (Automatic Transfer Switch) for automatic switching between grid and generator power. For larger systems, parallel operation and PLC control systems can be used to manage multiple units and ensure stable power distribution.

Q: What maintenance is required during operation?

A: Regular maintenance includes engine oil and filter replacement, cooling system inspection, and electrical connection checks. Maintenance intervals depend on operating hours and load conditions, and are essential for maintaining long-term stable performance.

Q: Can multiple generators operate together in one system?

A: Yes. With a parallel synchronization system, multiple generator sets can operate together and share load automatically. This is commonly used in large industrial facilities and critical power projects requiring higher capacity and redundancy.

Q: What factors affect the lifespan of an industrial generator?

A: The lifespan depends mainly on operating load level, maintenance quality, fuel condition, and environmental factors such as temperature, dust, and humidity. Proper operation under rated load and regular maintenance significantly extends service life.

We're well-known as one of the leading industrial diesel generator set manufacturers and suppliers in China. We warmly welcome you to buy advanced industrial diesel generator set at competitive price from our factory. If you have any enquiry about pricelist and quotation, please feel free to email us.

(0/10)

clearall